MOPTIM Mocean 4000 SLO-OCT Optical Coherence Tomography


Overview

  • High scanning speed at 80,000 A-scans/s
  • Up to 100 images averaging enhances the quality of OCT imaging
  • 3mm scan depth shows better details of the vitreous, retina and choroid
  • Real-time 45° SLO retinal imagin
  • SLO-based retinal tracking
  • 16mm angle-to-angle scan
  • Comprehensive analysis of retina, glaucoma and cornea
  • Upgrade to VASCAN OCTA analysis (optional)

Share:

Superior OCT image quality with up to 100 times averaging

Mocean 4000 captures 100 images in less than one second, and merge them together to create a high definition image with minimized speckle noise

5 μm axial optical resolution (3 μm digital)

High definition OCT imaging reveals hidden pathological changes

High quality real-time SLO + Eye tracking

The key advantage of Mocean® 4000 system is the simultaneous acquisition of cross-sectional OCT imaging and 47 degrees fundus imaging based on Scanning Laser Ophthalmoscope (SLO). It gives you an overview of the retina so you can easily locate the lesion area before acquisition. Moreover, the system captures up to 50 SLO fundus images within one second in order to generate an HD fundus imaging. 

To minimize the artifacts caused by eye drift and micro saccades, Mocean®  uses SLO-based eye tracker. It performs 100 times tracking per second with 10 microns tracking accuracy and more than 95% success rate, which gives you more confidence in practice.enhanced signal-to-noise ratio.

High scanning speed at 80,000 A-scans/s

80,000 A-scans/s allows 1.5s examination for high definition scan, and 1s for 3D scan.

16mm angle-to-angle analysis

16mm angle-to-angle anterior scan with data analysis.

Epithelial thickness mapping

Provides 6mm diameter cornea epithelium thickness map, which is an important part of diagnostics in refractive surgery, with many important clinical applications.

Comprehensive GLAUCOMA analysis (ONH/GCC)

For comprehensive glaucoma analysis, Mocean 4000 offers two scan patterns, glaucoma cube scan in macular area for GCC analysis and glaucoma cube scan in disc area for ONH analysis. Evenly distributed sampling point with 200 x 200 A-scans provides reliable information for early glaucoma detection and management.

Deep Choroidal Imaging (DCI) mode

Using Deep Choroidal Imaging for detection of choroidal neovascularization.

Comprehensive software analysis and free upgrade

The Mocean® 4000 system provides 8 scan patterns to help you improve diagnostic efficiency:

Retina (HD line, Six-Radial lines, Multi, 3D Cube)

Glaucoma (Glaucoma Disc for ONH analysis, Glaucoma Macular for GCC analysis)

Cornea (HD line, Six-Radial lines, Angle-to-Angle)

The software analysis features are always up-to-date and free for upgrade (excluding OCTA module).

Optional VASCAN™ OCTA Module

*VASCAN™ OCT Angiography module is an optional software module of Mocean 4000.

Optical Coherence Tomography Angiography (OCTA) is a new non-invasive imaging technique that allows the detailed study of flow within the vascular structure of the eye without the need of dye injections.

· Ultraclear angiographic imaging powered by COMAG algorithm using phase and amplitude signals

· Widefield OCTA imaging up to 12 mm x 8 mm

Specifications

OCT Imaging

Methodology Spectral Domain OCT
Optical source Super luminescent diode (SLD), 840 nm
Scan speed 80,000 A-scans/s
Axial resolution (optical) 5 microns (optical), 2.7 microns (digital)
Transverse resolution 15 microns (optical), 3 microns (digital)
A-scan depth 3 mm
Diopter range -20 to + 20 diopters
Scan patterns Macular: HD line scan (6 / 12 mm), 3D scan (6 mm x 6 mm), 6-line radial scan, Multi (X-Y: 5 x 5) Disc: 3D scan (6 mm x 6 mm)
Anterior: HD line scan (6 / 16mm), 6-line radial scan

Fundus Imaging

Methodology Line scanning laser ophthalmoscopy (LSLO)
Minimum pupil diameter 3.0 mm
Field of view 45±1 degrees

VASCAN™ OCTA MODULE (Essential / Advance optional)

Scanning volume/area 3mm x 3mm     256 x 256 A-scans
6mm x 6mm     512 x 512 A-scans
8mm x 8mm     512 x 512 A-scans
12mm x 8 mm      540 x 360 A-scans
Algorithm C-OMAG
Segmentation options Encoded, Vitreousretina Intrerface(VRI), Superfcial retina, Deepfcial retinal, Avascular, Choriocapillaris, Choriod, Custom
Quantitative analysis Yes

Electrical and Physical

Weight 30.5 kg
Dimension 532 mm (L) x 360 mm (W) x 540 mm (H)
Source voltage AC 100 - 240 V
Frequency 50 Hz - 60 Hz
Power input 90 VA